Hi Wiotte Fabrice,

 

Figure 59 of the AD9852 datasheet shows the supply current consumption of AD9852 for 2 configurations.

Figure 60 shows current consumption by each four function:

  • Control DAC
  • output scaling multiplier
  • comparator
  • inverse sinc filter

 

If it is okay for you to reduce sample rate, then that would also save a lot of power. Say if you only need max fout of 75MHz, 188MHz sampling clock would be ok. 75MHz is 40% of 188MHz.

Running the supply voltage down to the minimum setting would also help.

 

Please let me know if that helps.

-Sitti