Testing the LMT overload and ADC overload by using of AD-FMComms2-EBZ + ZED Board ,IIO OSCILLOSCOPE. Monitor the voltage value at the output of the Control Output pins by setting the 0x035 as 0x07. When the Gain Control Modes is in Slow_attack mode, the voltage at the control ouput pins are correct that indicates the LMT overload and AGC overload are correct. But in MGC mode, the voltage at the control output pins are incorrect. The ADC is overloaded and LMT is not overloaded even if the Rx power is cut off, and the threshold setting are all default. Could you please help to verify the overload funtions in MGC mode and tell us where we need to notice?
Thanks and best regareds,