Re: Parameters to consider for selecting a SFCW transceiver IC.

$
0
0

few requirements:

dynamic range: >100dB

Resolution: <5cm

Range: <3m

noise floor: <-150dBm/Hz

high receiver sensitivity

low receiver noise figure: <3dB

low IF bandwidth

freq range: 1GHz to 5GHz

can AD9361 complete the needs?

 

also i need unmodulated (continuous wave) bandwidth at receiver with if bandwidth around 50 kHz. AD9361 supports various modulations which are not required for my application. so can you suggest me whether this ic will meet the specification or any other ic can meet the spec. plz reply as soon as possible.