Hello Luke,
The specification in Table 2 is a typographical error and will be corrected in the next Revision of the data sheet.
The value of 1.0 µA max should be in the "-40°C to +125°C" column as it is in Table 1.
Regards,
Sean
Hello Luke,
The specification in Table 2 is a typographical error and will be corrected in the next Revision of the data sheet.
The value of 1.0 µA max should be in the "-40°C to +125°C" column as it is in Table 1.
Regards,
Sean