Re: AD5410, necessary interval between RESET command and available to control registers write

$
0
0

Hi, Aoki-san!

 

The data sheet did not include a time for the software reset. The part has a minimum time specified of 40us. This is guaranteed by design not production tested so I think that 1ms will be good enough. The data sheet is currently being updated so this 40us number will be included in the next revision.

 

Regards,

Mark