Re: HMC921LP4E @ 400 MHz Reference Design

$
0
0

Hi Lurie,

 

If you make the following modifications on 450 MHz tune circuit,

C1:18 pF

L2:8.2 nH

 

You should get 400 MHz match Please also refer to attached document.

 

Best,

Kagan