Re: How to configure display timing via EDID

Another interesting test is after the PC has failed to get the correct edid, toggle the HPA line to force the PC to re-read the edid and see if it comes in clean.  This thread shows how to do it

https://ez.analog.com/message/52926#52926

The registers are the same for the 7611 and 7619

 

Another way to toggle the HPA line is, if it has a 10k pullup to DDC_5V then you can just tap a 220 Ohm resistor from HPA to ground.  This will glitch HPA causing the PC to re-read the source.